CTZ
베어링 지식 센터

테이크업 베어링(UCT) 조정 가이드

테이크업 베어링 유닛이 무엇인지, 어디에 쓰이는지, 그리고 컨베이어 프레임을 옮기지 않고 UCT로 벨트 장력을 조정하는 방법을 안내합니다.

Installation업데이트: 2026-08-24CTZ Technical Team

목차

  1. 테이크업 베어링이란
  2. 적용 처
  3. UCT 구조
  4. 벨트 장력 조정
  5. 설치 단계
  6. 일반적 오류

What is a take-up bearing

A take-up bearing unit (UCT) pairs a UC insert bearing with a slide T-housing. The housing can move along a slot so the shaft position can be adjusted to tighten or loosen a belt or chain.

It is used where fixed-center bearings cannot provide the tension adjustment a conveyor or elevator needs.

Where it is used

UCT units are common on belt conveyors, bucket elevators and other equipment where belt stretch or chain wear must be compensated without moving the frame.

They are usually mounted on a take-up frame with a threaded rod or bolt that drives the slide.

UCT structure

The T-housing has a slot that fits the take-up frame. A UC insert (for example UC205 in a UCT205) carries the shaft. The whole unit slides as the adjustment bolt turns.

Like other mounted units, the insert provides self-alignment and set-screw locking for the shaft.

How to adjust belt tension

Loosen the lock nuts, then turn the adjustment bolt to slide the unit along the slot. Move it until the belt tension is correct, then re-tighten the lock nuts and the shaft set screws.

Adjust gradually and re-check tension. Over-tightening shortens belt life and increases bearing load; too loose causes slippage and uneven wear.

Installation steps

Mount the T-housing on the take-up frame, confirm the shaft and bore, tighten the insert set screws, then position the unit using the adjustment bolt and secure the lock nuts.

Rotate the shaft by hand where possible and check for abnormal resistance before returning the equipment to normal operation.

Common mistakes

Common errors include adjusting only one side of a multi-unit system, over-tightening the belt, leaving lock nuts loose, and ignoring shaft misalignment.

If the unit runs hot or noisy after adjustment, stop and recheck tension, locking and alignment before continuing.

Typical UCT models

ModelBoreUsed in
UCT20525 mm (1 in)Small conveyors
UCT21050 mm (2 in)Medium conveyors
UCT21575 mm (3 in)Heavy conveyors

Adjustment checklist

  • Loosen lock nuts first.
  • Turn adjustment bolt gradually.
  • Re-check belt tension.
  • Re-tighten lock nuts and set screws.
  • Hand-rotate and inspect.

Common mistakes

MistakeResultBetter practice
Over-tightening beltBelt and bearing overloadAdjust gradually, re-check tension
Loose lock nutsUnit drifts, misalignmentSecure after adjustment
One-side onlyUneven tensionAdjust matched units together

핵심 요약

  • A UCT unit slides in a slot to adjust belt or chain tension without moving the frame.
  • Adjust gradually, then secure lock nuts and set screws.
  • Avoid over-tightening, which shortens belt and bearing life.

Frequently Asked Questions

What is a take-up bearing used for?

It adjusts belt or chain tension on conveyors and elevators without moving the equipment frame, using a sliding T-housing.

Is UCT205 the same bore as UC205?

Yes, UCT205 uses a UC205 insert with a 25 mm bore; only the slide T-housing is added.

How tight should the belt be?

Tight enough to avoid slippage, not so tight that it overloads the belt and bearing. Adjust gradually and re-check.

귀사 시장에 필요한 베어링 유닛을 찾고 계십니까?

모델 번호, 수량, 포장 요구사항 및 도착 항구를 보내주세요.

문의 보내기
테이크업 베어링(UCT) 조정 가이드 | CTZ